REGENERATIVE CYCLE
This section will
introduce one such cycle - the ideal regenerative Rankine cycle, which
increases the fluid average temperature during the heat addition process. To save fuel, efforts are constantly made to
improve the efficiency of the cycle on which steam power plants operate. The
general idea is to increase the fluid average temperature during heat addition
and decrease the fluid temperature during heat rejection.
Increasing the temperature of the feedwater (water
leaving the pump and entering the boiler) can be considered. This
is accomplished by extracting stream from the turbine to heat the feedwater.
This process is called regeneration and the heat exchanger where heat is
transferred from steam to feedwater is called a regenerator, or a feedwater
heater. There are actually two main types of feedwater heaters. If the steam
mixes with the compressed water from the pump, it is an open feedwater heater.
If the steam does not mix with the compressed water from the pump, it is a
closed feedwater heater.
schematic of a power plant running an ideal regenerative rankine cycle with feed water heater. |
T-S diagram of ideal regenerative rankine cycle with feed water heater |
In an ideal condition, the water leaves the
heater as a saturated liquid at the heater pressure. The schematic of a steam
power plant with one open feedwater heater is shown on the left. In an ideal
regenerative Rankine cycle with an open feedwater heater, steam from the boiler
(state 1) expands in the turbine to an intermediate pressure (state 2). At this
state, some of the steam is extracted and sent to the feedwater heater, while
the remaining steam in the turbine continues to expand to the condenser
pressure (state 3). Saturated water from the condenser (state 4) is pumped to
the feedwater pressure and send to the feedwater heater (state 5). At the feedwater
heater, the compressed water is mixed with the steam extracted from the turbine
(state 2) and exits the feedwater heater as saturated water at the heater
pressure (state 6). Then the saturated water is pumped to the boiler pressure
by a second pump (state 7).The water is heated to a higher temperature in the
boiler (state 1) and the cycle repeats again.
Note
that the mass flow rate at each component is different. If 1 kg steam enters
the turbine, m kg is extracted to the feedwater heater and (1-m) kg continues
to expand to the condenser pressure. So if the mass flow rate at the boiler is M,
then the mass flow rate from other components are:Condenser: M (1-m)
Pump 1: M (1-m)
Feedwater Heater: Mm +M(1-m) = M
Pump 2 : M
For convenience, heat and work interactions for regenerative Rankine cycle is expressed per unit mass of steam flowing through the boiler. They are:
Heat Input: Q IN = h1 – h7
Heat Output: Q OUT = (1 - m)(h4 – h3)
Work Output: W TURBINE OUT= (h1 – h2) + (1 - m)(h2 – h3)
Work input: W PUMP IN = (1 - m)(h5 – h4) + (h7 – h6)
Open
feedwater heaters are simple and inexpensive, and can also bring the feedwater
to saturated state. However, each feedwater needs a separate pump which adds to
the cost.